Our test facilities include:
- **IMV A74/EM10HAG 74 kN, equipped with RT1200 and RT600 slip tables and a guided 1200x1200 head expander.
- **ACS AV 4200 C10, with 4200 lt internal volume, capable of performing thermal cycling tests at ±10°C/min within a temperature range of -60°C to +180°C, with humidity control (10-95% in the +10°C/+95°C range). The chamber can operate independently or be coupled with the 74 kN shaker.
- **IMV i250/EM2502, with maximum acceleration of 115 g. This shaker can be coupled with a RT750 slip table.
- **IMV i230/EM2301, with maximum acceleration of 125 g and maximum frequency of 3300 Hz.
- Climatic chamber Angelantoni AV 1200 C5 with 1200 lt internal volume, temperature range from -75° to +180° (5°/min up/down temperature ramp). The chamber can be coupled with both IMV shakers or used alone.
- Measurement sensors such as: impact hammers, three-axial and mono-axial accelerometers, intensity probe, strain gauges, and microphones.
- Shaker Brüel & Kjær 4810 for modal analysis and sensor calibration in the range 0-18 kHz.
- Intensity probe GRAS 50AI-L for acoustic intensimetry.
- Data acquisition systems: 2 Siemens SCADAS Mobile, capable of measuring accelerometers and strain gauges, and 1 SCADAS XS. The acquisition systems can also be combined, allowing for up to 52 acquisition channels.